Chromium Code Reviews| Index: src/ic.cc |
| diff --git a/src/ic.cc b/src/ic.cc |
| index ea0c1fbbe1d70438ee2983ee0d682ef5d3700f24..22a88a5be8707adfc31152c5ddbdb24658dc6da0 100644 |
| --- a/src/ic.cc |
| +++ b/src/ic.cc |
| @@ -2572,6 +2572,22 @@ static BinaryOpIC::TypeInfo InputState(BinaryOpIC::TypeInfo old_type, |
| } |
| +static bool TryToInt32(Handle<Object> object, int32_t* result) { |
| + if (object->IsSmi()) { |
| + *result = Smi::cast(*object)->value(); |
| + return true; |
| + } |
| + if (object->IsHeapNumber()) { |
| + double value = HeapNumber::cast(*object)->value(); |
| + if (TypeInfo::IsInt32Double(value)) { |
| + *result = static_cast<int32_t>(value); |
| + return true; |
| + } |
| + } |
| + return false; |
| +} |
| + |
| + |
| RUNTIME_FUNCTION(MaybeObject*, BinaryOp_Patch) { |
| ASSERT(args.length() == 3); |
| @@ -2580,6 +2596,21 @@ RUNTIME_FUNCTION(MaybeObject*, BinaryOp_Patch) { |
| Handle<Object> right = args.at<Object>(1); |
| int key = args.smi_at(2); |
| Token::Value op = BinaryOpStub::decode_op_from_minor_key(key); |
| + |
| + bool previous_has_fixed_right_arg = |
| + BinaryOpStub::decode_has_fixed_right_arg_from_minor_key(key); |
| + int previous_fixed_right_arg_value = |
| + BinaryOpStub::decode_fixed_right_arg_value_from_minor_key(key); |
| + |
| + int32_t value; |
| + bool new_has_fixed_right_arg = |
| + op == Token::MOD && |
| + TryToInt32(right, &value) && |
| + BinaryOpStub::can_encode_arg_value(value) && |
| + (!previous_has_fixed_right_arg || |
|
Jakob Kummerow
2013/05/23 12:05:43
I still disagree with this condition, as discussed
Sven Panne
2013/05/23 14:39:20
Ooops, forgot that. Fixed.
|
| + previous_fixed_right_arg_value == value); |
| + int32_t new_fixed_right_arg_value = new_has_fixed_right_arg ? value : 1; |
| + |
| BinaryOpIC::TypeInfo previous_left, previous_right, unused_previous_result; |
| BinaryOpStub::decode_types_from_minor_key( |
| key, &previous_left, &previous_right, &unused_previous_result); |
| @@ -2597,40 +2628,51 @@ RUNTIME_FUNCTION(MaybeObject*, BinaryOp_Patch) { |
| BinaryOpIC::TypeInfo new_overall = Max(new_left, new_right); |
| BinaryOpIC::TypeInfo previous_overall = Max(previous_left, previous_right); |
| - if (new_overall == BinaryOpIC::SMI && previous_overall == BinaryOpIC::SMI) { |
| - if (op == Token::DIV || |
| - op == Token::MUL || |
| - op == Token::SHR || |
| - kSmiValueSize == 32) { |
| - // Arithmetic on two Smi inputs has yielded a heap number. |
| - // That is the only way to get here from the Smi stub. |
| - // With 32-bit Smis, all overflows give heap numbers, but with |
| - // 31-bit Smis, most operations overflow to int32 results. |
| - result_type = BinaryOpIC::NUMBER; |
| - } else { |
| - // Other operations on SMIs that overflow yield int32s. |
| - result_type = BinaryOpIC::INT32; |
| + if (previous_has_fixed_right_arg == new_has_fixed_right_arg) { |
| + if (new_overall == BinaryOpIC::SMI && previous_overall == BinaryOpIC::SMI) { |
| + if (op == Token::DIV || |
| + op == Token::MUL || |
| + op == Token::SHR || |
| + kSmiValueSize == 32) { |
| + // Arithmetic on two Smi inputs has yielded a heap number. |
| + // That is the only way to get here from the Smi stub. |
| + // With 32-bit Smis, all overflows give heap numbers, but with |
| + // 31-bit Smis, most operations overflow to int32 results. |
| + result_type = BinaryOpIC::NUMBER; |
| + } else { |
| + // Other operations on SMIs that overflow yield int32s. |
| + result_type = BinaryOpIC::INT32; |
| + } |
| } |
| - } |
| - if (new_overall == BinaryOpIC::INT32 && |
| - previous_overall == BinaryOpIC::INT32) { |
| - if (new_left == previous_left && new_right == previous_right) { |
| - result_type = BinaryOpIC::NUMBER; |
| + if (new_overall == BinaryOpIC::INT32 && |
| + previous_overall == BinaryOpIC::INT32) { |
| + if (new_left == previous_left && new_right == previous_right) { |
| + result_type = BinaryOpIC::NUMBER; |
| + } |
| } |
| } |
| - BinaryOpStub stub(key, new_left, new_right, result_type); |
| + BinaryOpStub stub(key, new_left, new_right, result_type, |
| + new_has_fixed_right_arg, new_fixed_right_arg_value); |
| Handle<Code> code = stub.GetCode(isolate); |
| if (!code.is_null()) { |
| #ifdef DEBUG |
| if (FLAG_trace_ic) { |
| PrintF("[BinaryOpIC in "); |
| JavaScriptFrame::PrintTop(isolate, stdout, false, true); |
| - PrintF(" ((%s+%s)->((%s+%s)->%s))#%s @ %p]\n", |
| + PrintF(" ((%s+%s", |
|
Sven Panne
2013/05/23 14:39:20
While debugging this, I cleaned this trace output
|
| BinaryOpIC::GetName(previous_left), |
| - BinaryOpIC::GetName(previous_right), |
| + BinaryOpIC::GetName(previous_right)); |
| + if (previous_has_fixed_right_arg) { |
| + PrintF("{%d}", previous_fixed_right_arg_value); |
| + } |
| + PrintF(")->((%s+%s", |
| BinaryOpIC::GetName(new_left), |
| - BinaryOpIC::GetName(new_right), |
| + BinaryOpIC::GetName(new_right)); |
| + if (new_has_fixed_right_arg) { |
| + PrintF("{%d}", new_fixed_right_arg_value); |
| + } |
| + PrintF(")->%s))#%s @ %p]\n", |
| BinaryOpIC::GetName(result_type), |
| Token::Name(op), |
| static_cast<void*>(*code)); |